• Both CurrentPage.Property["TopNavigationRoot"] Session["TopNavigationRoot"] are null!

Shock Absorbing Element DEFORM plus® RMP

Due to the guidance at the fastening screw this version allows additional light lateral forces.

RINGFEDER® DEFORM plus R

metric inch
CAD Typ Wmax (20°C)/6h Wmax (20°C)/1h Fdyn(20°C) ~ 2xF stat(20°C) smax D' D1. DB L DG TE Gw
Joule Joule kN mm mm mm mm mm mm mm kg
R30 76 7,5 (with 1,1 m/s) 18 45 30 36 6 14 0,047
R45 240 15 (with 1,4 m/s) 27 68 45 54 8 17 0,085
R60 560 30 (with 2,0 m/s) 36 91 90 72 12 17 0,240
R90 1800 65 (with 3,2 m/s) 54 137 90 108 16 24 0,750
R30MP 57 8 (with 1,1 m/s) 13 45 30 37 42 8 16 0,700
R45MP 180 20 (with 1,4 m/s) 19 65 45 57 63 12 25 0,160
R60MP 420 40 (with 2,0 m/s) 25 90 60 71 85 16 22 0,360
R90MP 1350 80 (with 3,2 m/s) 37 130 90 112 127 24 28 1,300
CAD Typ Wmax (20°C)/6h Wmax (20°C)/1h Fdyn(20°C) ~ 2xF stat(20°C) smax D' D1. DB L DG TE Gw
ft-lbs ft-lbs lbs inch inch inch inch inch mm inch lbs
R30 56 1,686 0.709 1.772 1.181 1.417 6 0.551 0.104
R30MP 42 1,798 0.512 1.772 1.181 1.457 1.654 8 0.630 1.543
R45 177 3,371 1.063 2.677 1.772 2.126 8 0.669 0.187
R45MP 133 4,495 0.748 2.559 1.772 2.244 2.480 12 0.984 0.353
R60 413 6,742 1.417 3.583 3.543 2.835 12 0.669 0.529
R60MP 310 8,989 0.984 3.543 2.362 2.795 3.346 16 0.866 0.794
R90 1,328 14,608 2.126 5.394 3.543 4.252 16 0.945 1.653
R90MP 996 17,979 1.457 5.118 3.543 4.409 5.000 24 1.102 2.866

SHOCK ABSORBING Elements / DEFORM plus® R/RMP

Reusable buffer for absorption of kinetic energies without additional spring.

The casing combines the function of a spring and a damper. It can be reused after a dynamic load. Dependent on the velocity, the maximum supporting load automatically adapts to the impact energy, which means that i.e. equal masses are retarded more softly at lower velocities. Working temperature: -10°C up to +50°C.

Ambient conditions:

The material is resistant to

  • Bleach liquor 3%
  • Sugar solution 30%
  • Hydrogen peroxide 10%
  • Ammonia 5%
  • Acetic acid 2%
  • Formic acid 2%
  • Linseed fatty acid
  • Tannic acid solution 20%
  • Lubrication grease and oil

A continuous contact with water should be avoided. In accordance with DIN 4012, building material class 2, the material is classified as non-combustible, dripping (off).

Login required

Please log in now to use the requested service

© RINGFEDER POWER TRANSMISSION