• Both CurrentPage.Property["TopNavigationRoot"] Session["TopNavigationRoot"] are null!

Shock Absorbing Element DEFORM plus® R

These shock absorbing units are repeatedly resilient and are supplied ready for assembly and incl. screw.

RINGFEDER® DEFORM plus R

metric inch
CAD Typ Wmax (20°C)/6h Wmax (20°C)/1h Fdyn(20°C) ~ 2xF stat(20°C) smax D' D1. DB L DG TE Gw
    Joule Joule kN mm mm mm mm mm mm mm kg
  R30 76   7,5 (with 1,1 m/s) 18 45 30   36 6 14 0,047
  R45 240   15 (with 1,4 m/s) 27 68 45   54 8 17 0,085
  R60 560   30 (with 2,0 m/s) 36 91 90   72 12 17 0,240
  R90 1800   65 (with 3,2 m/s) 54 137 90   108 16 24 0,750
  R30MP   57 8 (with 1,1 m/s) 13 45 30 37 42 8 16 0,700
  R45MP   180 20 (with 1,4 m/s) 19 65 45 57 63 12 25 0,160
  R60MP   420 40 (with 2,0 m/s) 25 90 60 71 85 16 22 0,360
  R90MP   1350 80 (with 3,2 m/s) 37 130 90 112 127 24 28 1,300
CAD Typ Wmax (20°C)/6h Wmax (20°C)/1h Fdyn(20°C) ~ 2xF stat(20°C) smax D' D1. DB L DG TE Gw
  ft-lbs ft-lbs lbs inch inch inch inch inch mm inch lbs
  R30 56   1,686 0.709 1.772 1.181   1.417 6 0.551 0.104
  R30MP   42 1,798 0.512 1.772 1.181 1.457 1.654 8 0.630 1.543
  R45 177   3,371 1.063 2.677 1.772   2.126 8 0.669 0.187
  R45MP   133 4,495 0.748 2.559 1.772 2.244 2.480 12 0.984 0.353
  R60 413   6,742 1.417 3.583 3.543   2.835 12 0.669 0.529
  R60MP   310 8,989 0.984 3.543 2.362 2.795 3.346 16 0.866 0.794
  R90 1,328   14,608 2.126 5.394 3.543   4.252 16 0.945 1.653
  R90MP   996 17,979 1.457 5.118 3.543 4.409 5.000 24 1.102 2.866

SHOCK ABSORBING Elements DEFORM plus® R/RMP

Reusable buffer for absorption of kinetic energies without additional spring.

The casing combines the function of a spring and a damper. It can be reused after a dynamic load. Dependent on the velocity, the maximum supporting load automatically adapts to the impact energy, which means that i.e. equal masses are retarded more softly at lower velocities.
Working temperature: -10°C up to +50°C.

Ambient conditions:

The material is resistant to

  • Bleach liquor 3%
  • Sugar solution 30%
  • Hydrogen peroxide 10%
  • Ammonia 5%
  • Acetic acid 2%
  • Formic acid 2%
  • Linseed fatty acid
  • Tannic acid solution 20%
  • Lubrication grease and oil

A continuous contact with water should be avoided. In accordance with DIN 4012, building material class 2, the material is classified as non-combustible, dripping (off).